Nashville's HVAC — Middle Tennessee (615) 908-2074 Free Estimate
Home AC Repair Heating & Furnace Repair System Replacement Maintenance Plans Ductwork & Air Quality Mini-Splits & Add-Ons Service Area The Comfort Zone About Get a Free Estimate

HVAC · Nashville, TN

New Ductwork: Sizing, Sealing and Insulation

A duct installation is judged by four things you cannot see once the ceiling is closed: how it was sized, how it was sealed, how it was insulated and whether anyone measured the leakage.

We respond immediately Licensed and insured local crews Free, no-obligation estimates

· by Michael Blair, Nashville's HVAC

Ductwork is the part of a heating and cooling system nobody sees once it is in. It runs through the attic, the crawl space or a dropped soffit, and after the insulation is blown back and the hatch is closed, the only evidence of how it was built is how the house feels and what the bill says. That makes a duct installation easy to do quickly and hard to check later.

These are the four things a new or replaced duct system should meet before it is called finished, drawn from the energy code and from ENERGY STAR, and they are the standard for our ductwork installation and repair service, whether the job is a whole system or a single run to a stubborn room.

How should new ductwork be sized?

By a design calculation, ACCA Manual D, not by matching the old trunk line. The Nashville and Davidson County energy code, which adopts the 2024 International Energy Conservation Code with local amendments, requires in R403.3.1 that ducts in one- and two-family homes be laid out and sized using ANSI/ACCA Manual D. Copying the old layout copies whatever was wrong with it, and a room that has always run hot or cold is often a duct sizing problem; our post on why one room is always hotter than the rest covers that case.

The same chapter, in R403.3.2, rules out using the spaces between studs or joists as ductwork or plenums. A joist bay with sheet metal nailed across the bottom and used as a return is a framing cavity, and a duct replacement is the time to give that return a real duct.

Why does duct sealing matter as much as sizing?

Because a correctly sized duct that leaks still delivers less air than the design says. ENERGY STAR’s duct sealing page puts the typical loss at about 20 to 30 percent of the air moving through a duct system, through leaks, holes and poorly connected ducts. In an attic, that conditioned air is lost to the hottest or coldest space on the property.

ENERGY STAR says to seal ducts with mastic sealant or metal tape and never with duct tape, which does not last. The energy code’s R403.3.6 requires the ductwork, air handler and filter boxes to be sealed, and R403.3.6.1 says an air handler shall be rated for leakage of no more than 2 percent of its design airflow when tested to ASHRAE 193. On a new system, every collar, take-off and boot joint should be sealed, including the ones at the register boxes that sit just above the ceiling.

How much insulation do ducts in an attic need?

At least R-8 for ducts 3 inches in diameter and larger, and R-6 for anything smaller. R403.3.3 of the Davidson County energy code sets those minimums for supply and return ducts outside the conditioned space, which in most houses means the vented attic or the crawl space. A replacement is the moment to check that the insulation is continuous, with no bare metal at the joints where the wrap was pulled back to seal them.

Do new ducts have to be leak-tested in Tennessee?

Not under the state rule; the test is optional. Tennessee’s residential energy rule, Tenn. Comp. R. & Regs. 0780-02-23-.02, adopts the 2018 International Energy Conservation Code but makes its duct testing and duct leakage sections optional. Davidson County’s 2024 code includes a duct system test in R403.3.7, measured at 25 pascals before or after the drywall goes up with a written report to the code official, and the UpCodes text of Metro’s code carries a note that the same state rule makes that section optional.

Optional is not the same as unimportant. A pressure test is the only way to know how much a new system leaks, and it is easiest to fix what it finds before insulation and ceilings cover the joints.

Metro Codes’ adopted codes list shows the 2024 energy and mechanical codes in effect in Davidson County since July 16, 2025, while the State Fire Marshal’s list shows the 2018 energy code for homes at the state level. Brentwood and the other Williamson County cities can confirm which they enforce; our page on HVAC in Brentwood covers the area. Whatever the code requires, you can ask for the test and the result in writing, and you can ask us for a free estimate on a new or replacement duct system.

Sources

FAQ

New Ductwork: Sizing, Sealing and Insulation — questions

Should ducts be sealed with mastic or foil tape?

Either mastic or metal tape works. ENERGY STAR recommends mastic sealant or metal tape and says never to use duct tape, because it does not last. Mastic suits irregular joints such as collars and boots, while metal tape suits straight seams. Every joint, including those at the register boxes, should be sealed.

What is ACCA Manual D?

It is the duct design manual from the Air Conditioning Contractors of America: one set of sizing principles and calculations that applies to every duct material. Nashville’s energy code requires it for ducts serving one or two dwelling units. The equipment is sized separately, by Manual S, from heating and cooling loads worked out with Manual J.

What R-value should attic ductwork have?

The 2024 energy code adopted in Davidson County requires supply and return ducts outside the conditioned space to be insulated to at least R-8 when they are 3 inches in diameter or larger, and R-6 when smaller. The insulation should be continuous over joints that were opened for sealing.

Can a framing cavity be used as a return duct?

Not under the 2024 energy code adopted in Davidson County, which rules out using the spaces between studs or joists as ductwork or plenums. A joist bay closed off with sheet metal and used as a return is a framing cavity, and a duct replacement is a good time to give that return a real duct.

How is a duct leakage test done?

Davidson County’s 2024 energy code describes it: the duct system is tested at a pressure of 25 pascals and the leakage measured, either at rough-in or after construction, with a written report to the code official. Tennessee’s state rule makes the test optional, so ask for it and the written result before ceilings cover the joints.

Free estimate

House too hot or too cold right now?

Tell Nashville's HVAC what the thermostat says and how the system is behaving, and you will get the estimate in writing, free and with no strings attached.

Call Chat Free Estimate
AC or furnace acting up?